Difference between revisions of "Diesel Version 5:Dual Enabled Functions"

From Train Control Systems Documentation
Jump to navigation Jump to search
en>Johnd
 
m (1 revision imported)
(No difference)

Revision as of 21:46, 10 December 2020

Since some throttles have a limited number of physical function buttons TCS created "Light Mode" and "Sound Mode". While in Light Mode function buttons will control lights, while in sound mode the function buttons will control sounds. To switch between the modes press function 8 twice in rapid succession and the decoder will announce mode you are now in, feedback can be disabled with CV176 "User Options 1 CV".
There are sometimes where you may want both a sound and a light to respond together with a single button press such as pressing F2 to blow the horn and blink the ditch lights, in this case you need the function to be "dual enabled"

NMRA CV 238
Dual Enabled Functions Part 1
Range of Values0-255
Default Value1

NMRA CV 238 - Dual Enabled Functions Part 1

This controls whether functions are Dual Enabled. To dual enable a light function take the value in the corresponding columns and sum them together, program that value into the CV

Function Button Value
F0 1
F1 2
F2 4
F3 8
F4 16
F5 32
F6 64
F7 128
NMRA CV 239
Dual Enabled Functions Part 2
Range of Values0-255
Default Value1

NMRA CV 239 - Dual Enabled Functions Part 2

This controls whether functions are Dual Enabled. To dual enable a light function take the value in the corresponding columns and sum them together, program that value into the CV

Function Button Value
F8 1
F9 2
F10 4
F11 8
F12 16
F13 32
F14 64
F15 128
NMRA CV 240
Dual Enabled Functions Part 3
Range of Values0-255
Default Value0

NMRA CV 240 - Dual Enabled Functions Part 3

This controls whether functions are Dual Enabled. To dual enable a light function take the value in the corresponding columns and sum them together, program that value into the CV

Function Button Value
F16 1
F17 2
F18 4
F19 8
F20 16
F21 32
F22 64
F23 128
NMRA CV 241
Dual Enabled Functions Part 4
Range of Values0-255
Default Value0

NMRA CV 241 - Dual Enabled Functions Part 4

This controls whether functions are Dual Enabled. To dual enable a light function take the value in the corresponding columns and sum them together, program that value into the CV

Function Button Value
F24 1
F25 2
F26 4
F27 8
F28 16