Difference between revisions of "CV 14"

From Train Control Systems Documentation
Jump to navigation Jump to search
tcs>Dan Mycio
m
 
m
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
{{Infobox CV
 
{{Infobox CV
 
|cv name=DC Mode Lights F0 & F9-F12
 
|cv name=DC Mode Lights F0 & F9-F12
|cv range=0-255
+
|cv range=0-63
 
|cv accepted=0-255
 
|cv accepted=0-255
 
|cv default=255
 
|cv default=255
Line 7: Line 7:
  
 
==NMRA CV 14 - Alternate Mode Function Status F9-F12==
 
==NMRA CV 14 - Alternate Mode Function Status F9-F12==
Indicates the status of each function (F9 through F12, & FL) when the unit is operating in alternate power (DC) mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored.
+
CV 14 configures the active/inactive status for each lighting function output (F9 through F12, & FL) when the unit is operating in alternate power (DC) mode, which cannot control the functions. If a function cannot be controlled, then the corresponding bit is ignored.
  
 +
If the bit for a function output is "cleared," this indicates the function is disabled on DC power. If the bit for a function output is "set," this indicates the function output is enabled on DC power. This configuration affects the physical outputs on the decoder, not the button numbers! If you have remapped a lighting output to a different button, that will not affect this configuration. Note also that you must set up this CV to use the correct lighting outputs, not button numbers.
  
If the bit for a function output is "cleared," this indicates the function is disabled on DC power. If the bit for a function output is "set," this indicates the function is enabled on DC power. CV 12 is a bitwise CV, where FL in the forward direction is controlled by bit 0, FL in the reverse direction is controlled by bit 1, bit 2 corresponds to F9, and Bit 5 corresponds to F12. See the chart below:
+
'''NOTE:''' ''If a lighting output has been programmed with a lighting effect, such as a Mars light, that feature will continue to operate while on DC power.''
  
 +
CV 14 is a bitwise CV, where F0 in the forward direction is controlled by bit 0, F0 in the reverse direction is controlled by bit 1, bit 2 corresponds to F9, and Bit 5 corresponds to F12. See the chart below:
 
{| class="wikitable" style="text-align: center;"
 
{| class="wikitable" style="text-align: center;"
 +
! colspan="4" |CV14 - DC Mode Lights
 
|-
 
|-
 +
!Bit
 
! scope="col" |Feature
 
! scope="col" |Feature
 
! scope="col" |Value
 
! scope="col" |Value
 +
!Default
 
|-
 
|-
! scope="row" |Function 0 Forward
+
|0
 +
! scope="row" |Function 0 FWD
 
|1
 
|1
 +
|ON
 
|-
 
|-
 
|-
 
|-
! scope="row" |Function 0 Reverse
+
|1
 +
! scope="row" |Function 0 REV
 
|2
 
|2
 +
|ON
 
|-
 
|-
 
|-
 
|-
 +
|2
 
! scope="row" |Function 9
 
! scope="row" |Function 9
 
|4
 
|4
 +
|ON
 
|-
 
|-
 
|-
 
|-
 +
|3
 
! scope="row" |Function 10
 
! scope="row" |Function 10
 
|8
 
|8
 +
|ON
 
|-
 
|-
 
|-
 
|-
 +
|4
 
! scope="row" |Function 11
 
! scope="row" |Function 11
 
|16
 
|16
 +
|ON
 
|-
 
|-
 
|-
 
|-
 +
|5
 
! scope="row" |Function 12
 
! scope="row" |Function 12
 
|32
 
|32
 +
|ON
 
|-
 
|-
|}
+
|}The SUM of the desired functions active while operating in DC mode must be programmed into CV 14. A value of 255 enables all light functions on DC power.
 +
 
 +
<noinclude>
 +
== See Also ==
  
The SUM of the desired functions active while operating in DC mode must be programmed into CV 14. A value of 255 enables all light functions on DC power.
+
* [[CV 13|CV 13 - DC Mode Function Status F1-F8]]
 +
* [[:Category:DC Mode|DC Mode]]
  
 
[[Category:Standard CV]]
 
[[Category:Standard CV]]
 
[[Category:Bitwise CV]]
 
[[Category:Bitwise CV]]
 
[[Category:DC_Mode]]
 
[[Category:DC_Mode]]
 +
</noinclude>

Latest revision as of 17:47, 4 November 2022

CV 14
DC Mode Lights F0 & F9-F12
Range of Values0-63
Accepted Values0-255
Default Value255

NMRA CV 14 - Alternate Mode Function Status F9-F12

CV 14 configures the active/inactive status for each lighting function output (F9 through F12, & FL) when the unit is operating in alternate power (DC) mode, which cannot control the functions. If a function cannot be controlled, then the corresponding bit is ignored.

If the bit for a function output is "cleared," this indicates the function is disabled on DC power. If the bit for a function output is "set," this indicates the function output is enabled on DC power. This configuration affects the physical outputs on the decoder, not the button numbers! If you have remapped a lighting output to a different button, that will not affect this configuration. Note also that you must set up this CV to use the correct lighting outputs, not button numbers.

NOTE: If a lighting output has been programmed with a lighting effect, such as a Mars light, that feature will continue to operate while on DC power.

CV 14 is a bitwise CV, where F0 in the forward direction is controlled by bit 0, F0 in the reverse direction is controlled by bit 1, bit 2 corresponds to F9, and Bit 5 corresponds to F12. See the chart below:

CV14 - DC Mode Lights
Bit Feature Value Default
0 Function 0 FWD 1 ON
1 Function 0 REV 2 ON
2 Function 9 4 ON
3 Function 10 8 ON
4 Function 11 16 ON
5 Function 12 32 ON

The SUM of the desired functions active while operating in DC mode must be programmed into CV 14. A value of 255 enables all light functions on DC power.


See Also