CV 123

From Train Control Systems Documentation
Revision as of 21:47, 16 July 2021 by TCSDanM (talk | contribs) (1 revision imported)
Jump to navigation Jump to search
CV 123
Prime Mover Selection
Range of Values0-255
Accepted Values0-(# of Prime Movers)
Default Value0

NMRA CV 123 - Prime Mover Selection

This CV is used to select which prime mover is active in the decoder. Select a value from the table below and program it into CV149 to select that prime mover. A notch change, power cycle, or turning the PM off and back on will be needed in order for the change to take effect.
Note the prime mover can be selected using Audio Assist™ (Menu 1.3) without the need for CV programming.