Diesel Version 5:CV 83
Revision as of 20:52, 19 September 2018 by en>Tcsdcc (→NMRA CV 83 (Speed Table))
NMRA CV 83 - Speed Table Step 17
The speed table is defined to be 28 bytes wide, consisting of 28 values for forward speeds. A digital controller that uses this table shall have at least 64 voltage drive levels and can have as many as 256 so that a smooth power curve can be constructed. Note that voltage drive levels are specified in integer values, in the same way as most other parameters. This means that a drive level of 1/4 maximum voltage corresponds to 0100000, not 0010000, as you would expect if the number specified a fraction with a fixed denominator, i.e. value 32 out of a fixed 128 levels (see Definitions section). See Speed Table for more information on how to setup the Speed Table.
Speed Table | |
---|---|
Range of Values | RANGE OF VALUES HERE |
Default Value | DEFAULT VALUE |