Diesel Version 5:CV 28
Jump to navigation
Jump to search
Bi-Directional Communication Configuration | |
---|---|
Range of Values | 0-255 |
Default Value | 19 |
NMRA CV 28 - Bi-Directional Communication Configuration (RailCom)
Used to configure decoder’s Bi-Directional Communication characteristics when RailCom is enabled in CV 29.
- Note If the decoder does not support a feature contained in this table, it shall not allow the corresponding bit to be set improperly (i.e. the bit should always contain its default value).
Feature | Description | Default | Value |
---|---|---|---|
Channel 1 | If enabled, Channel 1 will broadcast the address. | ON | 1 |
Channel 2 | If enabled, Channel 2 will send and receive data and provide acknowledgements. | ON | 2 |
Programming Address 253 | Serves as a programming lock. If this setting is disabled, programming address 253 will be locked. | ON | 16 |