NMRA CV 27 - Decoder Automatic Stopping Configuration
This CV is used to configure which conditions on the rails will cause the decoder to automatically stop.
| Bit | Option | Value | Default |
|---|---|---|---|
| 0 | Set to Enable Auto Stop in the presence of an asymmetrical DCC signal which is more positive on the right rail | 1 | OFF |
| 1 | Set to Enable Auto Stop in the presence of an asymmetrical DCC signal which is more positive on the left rail | 2 | OFF |
| 2 | Set to Enable Auto Stop in the presence of an Signal Controlled Influence cutout signal | 4 | OFF |
| 3 | [Reserved/Not Used] | N/A | |
| 4 | Set to Enable Auto Stop in the presence of reverse polarity DC | 16 | OFF |
| 5 | Set to Enable Auto Stop in the presence forward polarity DC | 32 | OFF |
| 6 | [Reserved/Not Used] | N/A | |
| 7 | [Reserved/Not Used] | N/A |