==NMRA CV 21 - Consist Lighting Control for Function 1 Through Function 8== | ==NMRA CV 21 - Consist Lighting Control for Function 1 Through Function 8== | ||
− | This CV is used to configure what functions will respond to user input on the consist address. This particular CV affects F1-F8. For each Bit which is set, that the function will respond to instructions addressed to the consist address ONLY. Each bit which is cleared indicates that the function will only respond to instructions addressed to the locomotive's individual address. F1 is controlled by bit 0; F8 by bit 7. | + | This CV is used to configure what functions will respond to user input on the consist address. This particular CV affects F1-F8. For each Bit which is set, that the function will respond to instructions addressed to the consist address ONLY. Each bit which is cleared indicates that the function will only respond to instructions addressed to the locomotive's individual address. F1 is controlled by bit 0; F8 by bit 7. |
− | To determine which functions are active, use the table below and combine the values of the functions you would like to have active, and program the ''sum'' into | + | To determine which functions are active, use the table below and combine the values of the functions you would like to have active, and program the ''sum'' into CV 21. By default, all functions are active on the consist address. |
+ | |||
+ | '''NOTE:''' WOWSound decoders prior to Version 5 and all non-sound decoders will always have all functions available on the Base Address. This CV, as well as [[CV 22]] can be used only to deny the use of a function while in a consist when the consist address is selected. | ||
{| class="wikitable" style="text-align: center;" | {| class="wikitable" style="text-align: center;" | ||
Line 75: | Line 77: | ||
*[[{{NAMESPACE}}:CV_156|Dual Prime Mover Delay]] | *[[{{NAMESPACE}}:CV_156|Dual Prime Mover Delay]] | ||
− | [[Category:Standard CV]][[Category:Bitwise CV]] | + | [[Category:Standard CV]] |
+ | [[Category:Bitwise CV]] |
Revision as of 15:24, 1 November 2022
|
NMRA CV 21 - Consist Lighting Control for Function 1 Through Function 8
This CV is used to configure what functions will respond to user input on the consist address. This particular CV affects F1-F8. For each Bit which is set, that the function will respond to instructions addressed to the consist address ONLY. Each bit which is cleared indicates that the function will only respond to instructions addressed to the locomotive's individual address. F1 is controlled by bit 0; F8 by bit 7.
To determine which functions are active, use the table below and combine the values of the functions you would like to have active, and program the sum into CV 21. By default, all functions are active on the consist address.
NOTE: WOWSound decoders prior to Version 5 and all non-sound decoders will always have all functions available on the Base Address. This CV, as well as CV 22 can be used only to deny the use of a function while in a consist when the consist address is selected.
Bit | Feature | Value | Default |
---|---|---|---|
0 | Function 1 | 1 | Control on Consist Addr |
1 | Function 2 | 2 | Control on Consist Addr |
2 | Function 3 | 4 | Control on Consist Addr |
3 | Function 4 | 8 | Control on Consist Addr |
4 | Function 5 | 16 | Control on Consist Addr |
5 | Function 6 | 32 | Control on Consist Addr |
6 | Function 7 | 64 | Control on Consist Addr |
7 | Function 8 | 128 | Control on Consist Addr |