Difference between revisions of "Diesel Version 5:CV 14"

From Train Control Systems Documentation
Jump to navigation Jump to search
Line 1: Line 1:
 +
{{Infobox CV
 +
|cv name=DC Mode Function Status F0 & F9-F12
 +
|cv range=0-255
 +
|cv accepted=0-255
 +
|cv default=255
 +
}}
 +
 
== NMRA CV 14 - Alternate Mode Function Status F9-F12 ==
 
== NMRA CV 14 - Alternate Mode Function Status F9-F12 ==
Indicates the status of each function (F9 through F12, & FL) when the unit is operating in alternate power mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored.
+
Indicates the status of each function (F9 through F12, & FL) when the unit is operating in alternate power (DC) mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored.
A value of "0" indicates the function is off, while a value of "1" indicates the function is on. FL in the forward direction is controlled by bit 0, FL in the reverse direction is controlled by bit 1. Bit 2 corresponds to F9, while Bit 5 corresponds to F12.
+
 
 +
 
 +
If the bit for a function output is "cleared," this indicates the function is disabled on DC power. If the bit for a function output is "set," this indicates the function is enabled on DC power. CV 12 is a bitwise CV, where FL in the forward direction is controlled by bit 0, FL in the reverse direction is controlled by bit 1, bit 2 corresponds to F9, and Bit 5 corresponds to F12. See the chart below:
 +
 
 +
{| class="wikitable" style="text-align: center;"
 +
|-
 +
! scope="col"| Feature
 +
! scope="col"| Value
 +
|-
 +
! scope="row"| Function 0 Forward
 +
| 1
 +
|-
 +
|-
 +
! scope="row"| Function 0 Reverse
 +
| 2
 +
|-
 +
|-
 +
! scope="row"| Function 9
 +
| 4
 +
|-
 +
|-
 +
! scope="row"| Function 10
 +
| 8
 +
|-
 +
|-
 +
! scope="row"| Function 11
 +
| 16
 +
|-
 +
|-
 +
! scope="row"| Function 12
 +
| 32
 +
|-
 +
|}
 +
 
 +
The SUM of the desired functions active while operating in DC mode must be programmed into CV 14. A value of 255 enables all light functions on DC power.
  
[[Category:DC_Mode]][[Category:Standard_CV]]
+
[[Category:Standard CV]]
 +
[[Category:Bitwise CV]]
 +
[[Category:DC_Mode]]

Revision as of 22:41, 2 April 2021

CV 14
DC Mode Function Status F0 & F9-F12
Range of Values0-255
Accepted Values0-255
Default Value255

NMRA CV 14 - Alternate Mode Function Status F9-F12

Indicates the status of each function (F9 through F12, & FL) when the unit is operating in alternate power (DC) mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored.


If the bit for a function output is "cleared," this indicates the function is disabled on DC power. If the bit for a function output is "set," this indicates the function is enabled on DC power. CV 12 is a bitwise CV, where FL in the forward direction is controlled by bit 0, FL in the reverse direction is controlled by bit 1, bit 2 corresponds to F9, and Bit 5 corresponds to F12. See the chart below:

Feature Value
Function 0 Forward 1
Function 0 Reverse 2
Function 9 4
Function 10 8
Function 11 16
Function 12 32

The SUM of the desired functions active while operating in DC mode must be programmed into CV 14. A value of 255 enables all light functions on DC power.