Difference between revisions of "Diesel Version 5:CV 4"
Jump to navigation
Jump to search
m (1 revision imported) |
|||
Line 1: | Line 1: | ||
− | {{Infobox | + | {{Infobox CV |
− | + | |cv name=Deceleration Rate | |
− | | | + | |cv range=0-255 |
− | | | + | |cv accepted=0-255 |
− | | | + | |cv default=60 |
− | | | ||
− | |||
}} | }} | ||
== NMRA CV 4 - Deceleration Rate == | == NMRA CV 4 - Deceleration Rate == | ||
− | Determines the decoder's deceleration rate. | + | Determines the decoder's deceleration rate. The formula for the deceleration rate shall be equal to ([the contents of CV 4]*0.896)/(number of speed steps in use). For example, if the contents of CV 4 = 2, then the deceleration is 0.064 seconds per speed step for a decoder when using 28 speed step mode. If the content of this parameter equals "0" then there is no programmed momentum during deceleration. |
− | in use). | + | |
+ | [[Category:Standard CV]] | ||
+ | [[Category:Motor]] |
Revision as of 19:46, 2 April 2021
|
NMRA CV 4 - Deceleration Rate
Determines the decoder's deceleration rate. The formula for the deceleration rate shall be equal to ([the contents of CV 4]*0.896)/(number of speed steps in use). For example, if the contents of CV 4 = 2, then the deceleration is 0.064 seconds per speed step for a decoder when using 28 speed step mode. If the content of this parameter equals "0" then there is no programmed momentum during deceleration.