Diesel Version 5:CV 27: Difference between revisions
m (1 revision imported) |
No edit summary |
||
| Line 1: | Line 1: | ||
== NMRA CV 27 - Decoder Automatic Stopping Configuration == | {{Infobox CV | ||
|cv name= Automatic Stopping Configuration | |||
|cv range=0-255 | |||
|cv accepted=0-63 | |||
|cv default=0 | |||
}} | |||
==NMRA CV 27 - Decoder Automatic Stopping Configuration== | |||
Used to configure which actions will cause the decoder to automatically stop. | Used to configure which actions will cause the decoder to automatically stop. | ||
Bit 0 = Enable/Disable Auto Stop in the presence of an asymmetrical DCC signal which is more positive on the | Bit 0 = Enable/Disable Auto Stop in the presence of an asymmetrical DCC signal which is more positive on the | ||
right rail. | right rail. | ||
{| class="wikitable" style="text-align: center;" | |||
|- | |||
! scope="col"| Feature | |||
! scope="col"| Value | |||
|- | |||
! scope="row"| Function 1 | |||
| 1 | |||
|- | |||
|- | |||
! scope="row"| Function 2 | |||
| 2 | |||
|- | |||
|- | |||
! scope="row"| Function 3 | |||
| 4 | |||
|- | |||
|- | |||
! scope="row"| Function 4 | |||
| 8 | |||
|- | |||
|- | |||
! scope="row"| Function 5 | |||
| 16 | |||
|- | |||
|- | |||
! scope="row"| Function 6 | |||
| 32 | |||
|- | |||
|- | |||
! scope="row"| Function 7 | |||
| 64 | |||
|- | |||
|- | |||
! scope="row"| Function 8 | |||
| 128 | |||
|- | |||
|} | |||
“0” = Disabled “1” = Enabled | “0” = Disabled “1” = Enabled | ||
Bit 1 = Enable/Disable Auto Stop in the presence of an asymmetrical DCC signal which is more positive on the left rail. | Bit 1 = Enable/Disable Auto Stop in the presence of an asymmetrical DCC signal which is more positive on the left rail. | ||
| Line 14: | Line 60: | ||
“0” = Disabled “1” = Enabled | “0” = Disabled “1” = Enabled | ||
Bits 6-7 = Reserved for future use. | Bits 6-7 = Reserved for future use. | ||
*Note If the decoder does not support a feature contained in this table, it shall not allow the corresponding bit to be set improperly (i.e. the bit should always contain it’s default value). | |||
Revision as of 22:34, 22 May 2021
Lua error: Internal error: The interpreter exited with status 1.
NMRA CV 27 - Decoder Automatic Stopping Configuration
Used to configure which actions will cause the decoder to automatically stop. Bit 0 = Enable/Disable Auto Stop in the presence of an asymmetrical DCC signal which is more positive on the right rail.
| Feature | Value |
|---|---|
| Function 1 | 1 |
| Function 2 | 2 |
| Function 3 | 4 |
| Function 4 | 8 |
| Function 5 | 16 |
| Function 6 | 32 |
| Function 7 | 64 |
| Function 8 | 128 |
“0” = Disabled “1” = Enabled Bit 1 = Enable/Disable Auto Stop in the presence of an asymmetrical DCC signal which is more positive on the left rail. “0” = Disabled “1” = Enabled Bit 2 = Enable/Disable Auto Stop in the presence of an Signal Controlled Influence cutout signal. “0” = Disabled “1” = Enabled Bit 3 = Reserved for Future Use Bit 4 = Enable/Disable Auto Stop in the presence of reverse polarity DC “0” = Disabled “1” = Enabled Bit 5 = Enable/Disable Auto Stop in the presence forward polarity DC. “0” = Disabled “1” = Enabled Bits 6-7 = Reserved for future use.
- Note If the decoder does not support a feature contained in this table, it shall not allow the corresponding bit to be set improperly (i.e. the bit should always contain it’s default value).