Difference between revisions of "Diesel Version 5:CV 13"
Jump to navigation
Jump to search
(modified table to be more like other examples.) |
|||
(One intermediate revision by one other user not shown) | |||
Line 1: | Line 1: | ||
{{Infobox CV | {{Infobox CV | ||
− | |cv name=DC Mode | + | |cv name=DC Mode Lights F1-F8 |
|cv range=0-255 | |cv range=0-255 | ||
|cv accepted=0-255 | |cv accepted=0-255 | ||
Line 6: | Line 6: | ||
}} | }} | ||
− | == NMRA CV 13 - DC Mode Function Status F1-F8 == | + | ==NMRA CV 13 - DC Mode Function Status F1-F8== |
Indicates the status of each function (F1 through F8) when the unit is operating in alternate power (DC) mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored. | Indicates the status of each function (F1 through F8) when the unit is operating in alternate power (DC) mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored. | ||
Line 12: | Line 12: | ||
{| class="wikitable" style="text-align: center;" | {| class="wikitable" style="text-align: center;" | ||
+ | |+CV 13 - DC Mode Functions 1-8 | ||
|- | |- | ||
− | ! scope="col"| Feature | + | !Bit |
− | ! scope="col"| Value | + | ! scope="col" |Feature |
+ | !Default | ||
+ | ! scope="col" |Value | ||
|- | |- | ||
− | ! scope="row"| Function 1 | + | |0 |
− | | 1 | + | ! scope="row" |Function 1 |
+ | |ON | ||
+ | |1 | ||
|- | |- | ||
|- | |- | ||
− | ! scope="row"| Function 2 | + | |1 |
− | | 2 | + | ! scope="row" |Function 2 |
+ | |ON | ||
+ | |2 | ||
|- | |- | ||
|- | |- | ||
− | ! scope="row"| Function 3 | + | |2 |
− | | 4 | + | ! scope="row" |Function 3 |
+ | |ON | ||
+ | |4 | ||
|- | |- | ||
|- | |- | ||
− | ! scope="row"| Function 4 | + | |3 |
− | | 8 | + | ! scope="row" |Function 4 |
+ | |ON | ||
+ | |8 | ||
|- | |- | ||
|- | |- | ||
− | ! scope="row"| Function 5 | + | |4 |
− | | 16 | + | ! scope="row" |Function 5 |
+ | |ON | ||
+ | |16 | ||
|- | |- | ||
|- | |- | ||
− | ! scope="row"| Function 6 | + | |5 |
− | | 32 | + | ! scope="row" |Function 6 |
+ | |ON | ||
+ | |32 | ||
|- | |- | ||
|- | |- | ||
− | ! scope="row"| Function 7 | + | |6 |
− | | 64 | + | ! scope="row" |Function 7 |
+ | |ON | ||
+ | |64 | ||
|- | |- | ||
|- | |- | ||
− | ! scope="row"| Function 8 | + | |7 |
− | | 128 | + | ! scope="row" |Function 8 |
+ | |ON | ||
+ | |128 | ||
|- | |- | ||
|} | |} | ||
− | The SUM of the desired functions active while operating in DC mode must be programmed into CV 13. A value of 255 enables all light functions on DC power. | + | The SUM of the desired functions active while operating in DC mode must be programmed into CV 13. A value of 255 enables all available light functions from 1 through 8 on DC power. |
[[Category:Standard CV]] | [[Category:Standard CV]] | ||
[[Category:Bitwise CV]] | [[Category:Bitwise CV]] | ||
[[Category:DC_Mode]] | [[Category:DC_Mode]] |
Latest revision as of 19:23, 15 July 2024
|
NMRA CV 13 - DC Mode Function Status F1-F8
Indicates the status of each function (F1 through F8) when the unit is operating in alternate power (DC) mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored.
If the bit for a function output is "cleared," this indicates the function is disabled on DC power. If the bit for a function output is "set," this indicates the function is enabled on DC power. CV 12 is a bitwise CV, where Bit 0 corresponds to F1, while Bit 7 corresponds to F8. See the chart below:
Bit | Feature | Default | Value |
---|---|---|---|
0 | Function 1 | ON | 1 |
1 | Function 2 | ON | 2 |
2 | Function 3 | ON | 4 |
3 | Function 4 | ON | 8 |
4 | Function 5 | ON | 16 |
5 | Function 6 | ON | 32 |
6 | Function 7 | ON | 64 |
7 | Function 8 | ON | 128 |
The SUM of the desired functions active while operating in DC mode must be programmed into CV 13. A value of 255 enables all available light functions from 1 through 8 on DC power.