Diesel Version 5:CV 14: Difference between revisions
m (1 revision imported) |
mNo edit summary |
||
| (2 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
== NMRA CV 14 - Alternate Mode Function Status F9-F12 == | {{Infobox CV | ||
Indicates the status of each function (F9 through F12, & FL) when the unit is operating in alternate power mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored. | |cv name=DC Mode Lights F0 & F9-F12 | ||
|cv range=0-255 | |||
|cv accepted=0-255 | |||
|cv default=255 | |||
}} | |||
==NMRA CV 14 - Alternate Mode Function Status F9-F12== | |||
Indicates the status of each function (F9 through F12, & FL) when the unit is operating in alternate power (DC) mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored. | |||
If the bit for a function output is "cleared," this indicates the function is disabled on DC power. If the bit for a function output is "set," this indicates the function is enabled on DC power. CV 12 is a bitwise CV, where FL in the forward direction is controlled by bit 0, FL in the reverse direction is controlled by bit 1, bit 2 corresponds to F9, and Bit 5 corresponds to F12. See the chart below: | |||
{| class="wikitable" style="text-align: center;" | |||
|- | |||
! scope="col" |Feature | |||
! scope="col" |Value | |||
|- | |||
! scope="row" |Function 0 Forward | |||
|1 | |||
|- | |||
|- | |||
! scope="row" |Function 0 Reverse | |||
|2 | |||
|- | |||
|- | |||
! scope="row" |Function 9 | |||
|4 | |||
|- | |||
|- | |||
! scope="row" |Function 10 | |||
|8 | |||
|- | |||
|- | |||
! scope="row" |Function 11 | |||
|16 | |||
|- | |||
|- | |||
! scope="row" |Function 12 | |||
|32 | |||
|- | |||
|} | |||
The SUM of the desired functions active while operating in DC mode must be programmed into CV 14. A value of 255 enables all light functions on DC power. | |||
[[Category:Standard CV]] | |||
[[Category:Bitwise CV]] | |||
[[Category:DC_Mode]] | |||
Latest revision as of 23:06, 2 April 2021
Lua error: Internal error: The interpreter exited with status 1.
NMRA CV 14 - Alternate Mode Function Status F9-F12
Indicates the status of each function (F9 through F12, & FL) when the unit is operating in alternate power (DC) mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored.
If the bit for a function output is "cleared," this indicates the function is disabled on DC power. If the bit for a function output is "set," this indicates the function is enabled on DC power. CV 12 is a bitwise CV, where FL in the forward direction is controlled by bit 0, FL in the reverse direction is controlled by bit 1, bit 2 corresponds to F9, and Bit 5 corresponds to F12. See the chart below:
| Feature | Value |
|---|---|
| Function 0 Forward | 1 |
| Function 0 Reverse | 2 |
| Function 9 | 4 |
| Function 10 | 8 |
| Function 11 | 16 |
| Function 12 | 32 |
The SUM of the desired functions active while operating in DC mode must be programmed into CV 14. A value of 255 enables all light functions on DC power.