Difference between revisions of "CV 21"
m (1 revision imported) |
|||
(2 intermediate revisions by 2 users not shown) | |||
Line 3: | Line 3: | ||
|cv range=0-255 | |cv range=0-255 | ||
|cv accepted=0-255 | |cv accepted=0-255 | ||
− | |cv default= | + | |cv default=0 |
}} | }} | ||
==NMRA CV 21 - Consist Lighting Control for Function 1 Through Function 8== | ==NMRA CV 21 - Consist Lighting Control for Function 1 Through Function 8== | ||
− | This CV is used to configure what functions will respond to user input on the consist address. This particular CV affects F1-F8. For each Bit which is set, that the function will respond to instructions addressed to the consist address ONLY. Each bit which is cleared indicates that the function will only respond to instructions addressed to the locomotive's individual address. F1 is controlled by bit 0; F8 by bit 7. | + | This CV is used to configure what functions will respond to user input on the consist address. This particular CV affects F1-F8. For each Bit which is set, that the function will respond to instructions addressed to the consist address ONLY. Each bit which is cleared indicates that the function will only respond to instructions addressed to the locomotive's individual address. F1 is controlled by bit 0; F8 by bit 7. |
− | To determine which functions are active, use the table below and combine the values of the functions you would like to have active, and program the ''sum'' into | + | To determine which functions are active, use the table below and combine the values of the functions you would like to have active, and program the ''sum'' into CV 21. By default, all functions are active on the consist address. |
+ | |||
+ | '''NOTE:''' WOWSound decoders prior to Version 5 and all non-sound decoders will always have all functions available on the Base Address. This CV, as well as [[CV 22]] can be used only to deny the use of a function while in a consist when the consist address is selected. | ||
{| class="wikitable" style="text-align: center;" | {| class="wikitable" style="text-align: center;" | ||
Line 21: | Line 23: | ||
! scope="row" |Function 1 | ! scope="row" |Function 1 | ||
|1 | |1 | ||
− | |Control on | + | |Control on Base Address |
|- | |- | ||
|- | |- | ||
Line 27: | Line 29: | ||
! scope="row" |Function 2 | ! scope="row" |Function 2 | ||
|2 | |2 | ||
− | |Control on | + | |Control on Base Address |
|- | |- | ||
|- | |- | ||
Line 33: | Line 35: | ||
! scope="row" |Function 3 | ! scope="row" |Function 3 | ||
|4 | |4 | ||
− | |Control on | + | |Control on Base Address |
|- | |- | ||
|- | |- | ||
Line 39: | Line 41: | ||
! scope="row" |Function 4 | ! scope="row" |Function 4 | ||
|8 | |8 | ||
− | |Control on | + | |Control on Base Address |
|- | |- | ||
|- | |- | ||
Line 45: | Line 47: | ||
! scope="row" |Function 5 | ! scope="row" |Function 5 | ||
|16 | |16 | ||
− | |Control on | + | |Control on Base Address |
|- | |- | ||
|- | |- | ||
Line 51: | Line 53: | ||
! scope="row" |Function 6 | ! scope="row" |Function 6 | ||
|32 | |32 | ||
− | |Control on | + | |Control on Base Address |
|- | |- | ||
|- | |- | ||
Line 57: | Line 59: | ||
! scope="row" |Function 7 | ! scope="row" |Function 7 | ||
|64 | |64 | ||
− | |Control on | + | |Control on Base Address |
|- | |- | ||
|- | |- | ||
Line 63: | Line 65: | ||
! scope="row" |Function 8 | ! scope="row" |Function 8 | ||
|128 | |128 | ||
− | |Control on | + | |Control on Base Address |
|- | |- | ||
|} | |} | ||
Line 75: | Line 77: | ||
*[[{{NAMESPACE}}:CV_156|Dual Prime Mover Delay]] | *[[{{NAMESPACE}}:CV_156|Dual Prime Mover Delay]] | ||
− | [[Category:Standard CV]][[Category:Bitwise CV]] | + | [[Category:Standard CV]] |
+ | [[Category:Bitwise CV]] |
Latest revision as of 18:22, 4 November 2022
|
NMRA CV 21 - Consist Lighting Control for Function 1 Through Function 8
This CV is used to configure what functions will respond to user input on the consist address. This particular CV affects F1-F8. For each Bit which is set, that the function will respond to instructions addressed to the consist address ONLY. Each bit which is cleared indicates that the function will only respond to instructions addressed to the locomotive's individual address. F1 is controlled by bit 0; F8 by bit 7.
To determine which functions are active, use the table below and combine the values of the functions you would like to have active, and program the sum into CV 21. By default, all functions are active on the consist address.
NOTE: WOWSound decoders prior to Version 5 and all non-sound decoders will always have all functions available on the Base Address. This CV, as well as CV 22 can be used only to deny the use of a function while in a consist when the consist address is selected.
Bit | Feature | Value | Default |
---|---|---|---|
0 | Function 1 | 1 | Control on Base Address |
1 | Function 2 | 2 | Control on Base Address |
2 | Function 3 | 4 | Control on Base Address |
3 | Function 4 | 8 | Control on Base Address |
4 | Function 5 | 16 | Control on Base Address |
5 | Function 6 | 32 | Control on Base Address |
6 | Function 7 | 64 | Control on Base Address |
7 | Function 8 | 128 | Control on Base Address |
Related: