− | {{Infobox | + | {{Infobox CV |
− | + | |cv name= BEMF Cutout | |
− | | | + | |cv range=0-126 |
− | | | + | |cv accepted=1-126 |
− | + | |cv default=0 | |
− | | | ||
− | | | ||
}} | }} | ||
Line 11: | Line 9: | ||
Contains a value between 1 and 126 that indicates the speed step above which the back EMF motor control cuts off. When 14 or 28 speed steps are used the LSB's of the value are truncated appropriately. A value of 0 means BEMF is always active. | Contains a value between 1 and 126 that indicates the speed step above which the back EMF motor control cuts off. When 14 or 28 speed steps are used the LSB's of the value are truncated appropriately. A value of 0 means BEMF is always active. | ||
− | [[Category:Standard CV]] | + | [[Category:Standard CV]][[Category:Motor]] |
Latest revision as of 22:43, 16 July 2021
|
NMRA CV 10 - BEMF Cutout
Contains a value between 1 and 126 that indicates the speed step above which the back EMF motor control cuts off. When 14 or 28 speed steps are used the LSB's of the value are truncated appropriately. A value of 0 means BEMF is always active.