Revision as of 23:11, 22 May 2021
|
NMRA CV 27 - Decoder Automatic Stopping Configuration
This CV is used to configure which conditions on the rails will cause the decoder to automatically stop.
Bit | Option | Value | Default |
---|---|---|---|
0 | Set to Enable Auto Stop in the presence of an asymmetrical DCC signal which is more positive on the right rail | 1 | OFF |
1 | Set to Enable Auto Stop in the presence of an asymmetrical DCC signal which is more positive on the left rail | 2 | OFF |
2 | Set to Enable Auto Stop in the presence of an Signal Controlled Influence cutout signal | 4 | OFF |
3 | [Reserved/Not Used] | N/A | |
4 | Set to Enable Auto Stop in the presence of reverse polarity DC | 16 | OFF |
5 | Set to Enable Auto Stop in the presence forward polarity DC | 32 | OFF |
6 | [Reserved/Not Used] | N/A | |
7 | [Reserved/Not Used] | N/A |