Difference between revisions of "Diesel Version 5:CV 14"
m (1 revision imported) |
m |
||
(2 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | == NMRA CV 14 - Alternate Mode Function Status F9-F12 == | + | {{Infobox CV |
− | Indicates the status of each function (F9 through F12, & FL) when the unit is operating in alternate power mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored. | + | |cv name=DC Mode Lights F0 & F9-F12 |
− | + | |cv range=0-255 | |
+ | |cv accepted=0-255 | ||
+ | |cv default=255 | ||
+ | }} | ||
+ | |||
+ | ==NMRA CV 14 - Alternate Mode Function Status F9-F12== | ||
+ | Indicates the status of each function (F9 through F12, & FL) when the unit is operating in alternate power (DC) mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored. | ||
+ | |||
+ | |||
+ | If the bit for a function output is "cleared," this indicates the function is disabled on DC power. If the bit for a function output is "set," this indicates the function is enabled on DC power. CV 12 is a bitwise CV, where FL in the forward direction is controlled by bit 0, FL in the reverse direction is controlled by bit 1, bit 2 corresponds to F9, and Bit 5 corresponds to F12. See the chart below: | ||
+ | |||
+ | {| class="wikitable" style="text-align: center;" | ||
+ | |- | ||
+ | ! scope="col" |Feature | ||
+ | ! scope="col" |Value | ||
+ | |- | ||
+ | ! scope="row" |Function 0 Forward | ||
+ | |1 | ||
+ | |- | ||
+ | |- | ||
+ | ! scope="row" |Function 0 Reverse | ||
+ | |2 | ||
+ | |- | ||
+ | |- | ||
+ | ! scope="row" |Function 9 | ||
+ | |4 | ||
+ | |- | ||
+ | |- | ||
+ | ! scope="row" |Function 10 | ||
+ | |8 | ||
+ | |- | ||
+ | |- | ||
+ | ! scope="row" |Function 11 | ||
+ | |16 | ||
+ | |- | ||
+ | |- | ||
+ | ! scope="row" |Function 12 | ||
+ | |32 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | The SUM of the desired functions active while operating in DC mode must be programmed into CV 14. A value of 255 enables all light functions on DC power. | ||
+ | |||
+ | [[Category:Standard CV]] | ||
+ | [[Category:Bitwise CV]] | ||
+ | [[Category:DC_Mode]] |
Latest revision as of 23:06, 2 April 2021
|
NMRA CV 14 - Alternate Mode Function Status F9-F12
Indicates the status of each function (F9 through F12, & FL) when the unit is operating in alternate power (DC) mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored.
If the bit for a function output is "cleared," this indicates the function is disabled on DC power. If the bit for a function output is "set," this indicates the function is enabled on DC power. CV 12 is a bitwise CV, where FL in the forward direction is controlled by bit 0, FL in the reverse direction is controlled by bit 1, bit 2 corresponds to F9, and Bit 5 corresponds to F12. See the chart below:
Feature | Value |
---|---|
Function 0 Forward | 1 |
Function 0 Reverse | 2 |
Function 9 | 4 |
Function 10 | 8 |
Function 11 | 16 |
Function 12 | 32 |
The SUM of the desired functions active while operating in DC mode must be programmed into CV 14. A value of 255 enables all light functions on DC power.