Diesel Version 5:CV 13: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
| Line 1: | Line 1: | ||
= | {{Infobox CV | ||
|cv name=DC Mode Function Status F1-F8 | |||
|cv range=0-255 | |||
|cv accepted=0-255 | |||
|cv default=255 | |||
}} | |||
[[Category: | == NMRA CV 13 - DC Mode Function Status F1-F8 == | ||
Indicates the status of each function (F1 through F8) when the unit is operating in alternate power (DC) mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored. | |||
If the bit for a function output is "cleared," this indicates the function is disabled on DC power. If the bit for a function output is "set," this indicates the function is enabled on DC power. CV 12 is a bitwise CV, where Bit 0 corresponds to F1, while Bit 7 corresponds to F8. See the chart below: | |||
{| class="wikitable" style="text-align: center;" | |||
|- | |||
! scope="col"| Feature | |||
! scope="col"| Value | |||
|- | |||
! scope="row"| Function 1 | |||
| 1 | |||
|- | |||
|- | |||
! scope="row"| Function 2 | |||
| 2 | |||
|- | |||
|- | |||
! scope="row"| Function 3 | |||
| 4 | |||
|- | |||
|- | |||
! scope="row"| Function 4 | |||
| 8 | |||
|- | |||
|- | |||
! scope="row"| Function 5 | |||
| 16 | |||
|- | |||
|- | |||
! scope="row"| Function 6 | |||
| 32 | |||
|- | |||
|- | |||
! scope="row"| Function 7 | |||
| 64 | |||
|- | |||
|- | |||
! scope="row"| Function 8 | |||
| 128 | |||
|- | |||
|} | |||
The SUM of the desired functions active while operating in DC mode must be programmed into CV 13. A value of 255 enables all light functions on DC power. | |||
[[Category:Standard CV]] | |||
[[Category:Bitwise CV]] | |||
[[Category:DC_Mode]] | |||
Revision as of 22:41, 2 April 2021
Lua error: Internal error: The interpreter exited with status 1.
NMRA CV 13 - DC Mode Function Status F1-F8
Indicates the status of each function (F1 through F8) when the unit is operating in alternate power (DC) mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored.
If the bit for a function output is "cleared," this indicates the function is disabled on DC power. If the bit for a function output is "set," this indicates the function is enabled on DC power. CV 12 is a bitwise CV, where Bit 0 corresponds to F1, while Bit 7 corresponds to F8. See the chart below:
| Feature | Value |
|---|---|
| Function 1 | 1 |
| Function 2 | 2 |
| Function 3 | 4 |
| Function 4 | 8 |
| Function 5 | 16 |
| Function 6 | 32 |
| Function 7 | 64 |
| Function 8 | 128 |
The SUM of the desired functions active while operating in DC mode must be programmed into CV 13. A value of 255 enables all light functions on DC power.