Difference between revisions of "Diesel Version 5:CV 2"

From Train Control Systems Documentation
Jump to navigation Jump to search
m (1 revision imported)
Line 1: Line 1:
{{Infobox
+
{{Infobox CV
|title = NMRA CV 2
+
|cv name=Vstart (Start Volts)
|header1 = Base Functionality
+
|cv range=0-255
|label2 = Range of Values
+
|cv accepted=0-255
|data2 = 0-255
+
|cv default=0
|label3 = Default Value
 
|data3 = 0
 
 
}}
 
}}
  
 
== NMRA CV 2 - Vstart (Start Volts) ==
 
== NMRA CV 2 - Vstart (Start Volts) ==
CV 2 Adds an offset voltage to the motor so that the locomotive starts moving at a faster speed. This is useful for speed matching or for locomotives without BEMF. this setting is also useful for inefficient electric motors which have require a higher voltage to overcome "stall current." Some motors may lurch or repeatedly stop and start if the start volts are too low. Increasing the start volts can improve performance by increasing the low-end power.  
+
CV 2 Adds an offset voltage to the motor so that the locomotive starts moving at a faster speed. This is useful for speed matching or for locomotives without BEMF. this setting is also useful for inefficient electric motors which have require a higher voltage to overcome "stall current." Some motors may lurch or repeatedly stop and start if the start volts are too low. Increasing the start volts can improve performance by increasing the low-end power. Vstart is also referred to as "boost" by some manufacturers.  
  
  
Line 15: Line 13:
  
 
Vstart is used to define the voltage drive level used as the start voltage on the motor.  The voltage drive levels shall correspond linearly to the voltage applied to the motor at speed step one, as a fraction of available rectified supply voltage. When the voltage drive level is equal to zero, there shall be zero voltage applied to the motor. When it is at maximum (255), the full available rectified voltage shall be applied.
 
Vstart is used to define the voltage drive level used as the start voltage on the motor.  The voltage drive levels shall correspond linearly to the voltage applied to the motor at speed step one, as a fraction of available rectified supply voltage. When the voltage drive level is equal to zero, there shall be zero voltage applied to the motor. When it is at maximum (255), the full available rectified voltage shall be applied.
 +
 +
[[Category:Standard CV]]
 +
[[Category:Motor]]

Revision as of 19:26, 2 April 2021

CV 2
Vstart (Start Volts)
Range of Values0-255
Accepted Values0-255
Default Value0

NMRA CV 2 - Vstart (Start Volts)

CV 2 Adds an offset voltage to the motor so that the locomotive starts moving at a faster speed. This is useful for speed matching or for locomotives without BEMF. this setting is also useful for inefficient electric motors which have require a higher voltage to overcome "stall current." Some motors may lurch or repeatedly stop and start if the start volts are too low. Increasing the start volts can improve performance by increasing the low-end power. Vstart is also referred to as "boost" by some manufacturers.


From the NMRA standard:

Vstart is used to define the voltage drive level used as the start voltage on the motor. The voltage drive levels shall correspond linearly to the voltage applied to the motor at speed step one, as a fraction of available rectified supply voltage. When the voltage drive level is equal to zero, there shall be zero voltage applied to the motor. When it is at maximum (255), the full available rectified voltage shall be applied.