= | {{Infobox CV | ||
|cv name=DC Mode Lights F1-F8 | |||
|cv range=0-255 | |||
|cv accepted=0-255 | |||
|cv default=255 | |||
}} | |||
[[Category: | ==NMRA CV 13 - DC Mode Function Status F1-F8== | ||
Indicates the status of each function (F1 through F8) when the unit is operating in alternate power (DC) mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored. | |||
If the bit for a function output is "cleared," this indicates the function is disabled on DC power. If the bit for a function output is "set," this indicates the function is enabled on DC power. CV 12 is a bitwise CV, where Bit 0 corresponds to F1, while Bit 7 corresponds to F8. See the chart below: | |||
{| class="wikitable" style="text-align: center;" | |||
|+CV 13 - DC Mode Functions 1-8 | |||
|- | |||
!Bit | |||
! scope="col" |Feature | |||
!Default | |||
! scope="col" |Value | |||
|- | |||
|0 | |||
! scope="row" |Function 1 | |||
|ON | |||
|1 | |||
|- | |||
|- | |||
|1 | |||
! scope="row" |Function 2 | |||
|ON | |||
|2 | |||
|- | |||
|- | |||
|2 | |||
! scope="row" |Function 3 | |||
|ON | |||
|4 | |||
|- | |||
|- | |||
|3 | |||
! scope="row" |Function 4 | |||
|ON | |||
|8 | |||
|- | |||
|- | |||
|4 | |||
! scope="row" |Function 5 | |||
|ON | |||
|16 | |||
|- | |||
|- | |||
|5 | |||
! scope="row" |Function 6 | |||
|ON | |||
|32 | |||
|- | |||
|- | |||
|6 | |||
! scope="row" |Function 7 | |||
|ON | |||
|64 | |||
|- | |||
|- | |||
|7 | |||
! scope="row" |Function 8 | |||
|ON | |||
|128 | |||
|- | |||
|} | |||
The SUM of the desired functions active while operating in DC mode must be programmed into CV 13. A value of 255 enables all available light functions from 1 through 8 on DC power. | |||
[[Category:Standard CV]] | |||
[[Category:Bitwise CV]] | |||
[[Category:DC_Mode]] | |||
Latest revision as of 19:23, 15 July 2024
Lua error: Internal error: The interpreter exited with status 1.
NMRA CV 13 - DC Mode Function Status F1-F8
Indicates the status of each function (F1 through F8) when the unit is operating in alternate power (DC) mode, which cannot control the functions. If a function can be controlled, then the corresponding bit is ignored.
If the bit for a function output is "cleared," this indicates the function is disabled on DC power. If the bit for a function output is "set," this indicates the function is enabled on DC power. CV 12 is a bitwise CV, where Bit 0 corresponds to F1, while Bit 7 corresponds to F8. See the chart below:
| Bit | Feature | Default | Value |
|---|---|---|---|
| 0 | Function 1 | ON | 1 |
| 1 | Function 2 | ON | 2 |
| 2 | Function 3 | ON | 4 |
| 3 | Function 4 | ON | 8 |
| 4 | Function 5 | ON | 16 |
| 5 | Function 6 | ON | 32 |
| 6 | Function 7 | ON | 64 |
| 7 | Function 8 | ON | 128 |
The SUM of the desired functions active while operating in DC mode must be programmed into CV 13. A value of 255 enables all available light functions from 1 through 8 on DC power.