Difference between revisions of "CV 28"

From Train Control Systems Documentation
Jump to navigation Jump to search
m (added noinclude to "related" section which should be standard practice.)
m
 
(6 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Infobox
+
{{Infobox CV
|title = NMRA CV 28
+
|cv name=RailCom Configuration  
|header1 = Bi-Directional Communication Configuration  
+
|cv range=0-255
|label2 = Range of Values
+
|cv accepted=0-255
|data2 = 0-255
+
|cv default=7 (Varies)
|label3 = Default Value
 
|data3 = 19
 
 
}}
 
}}
  
== NMRA CV 28 - Bi-Directional Communication Configuration (RailCom) ==
+
==NMRA CV 28 - Bi-Directional Communication Configuration (RailCom®)==
Used to configure decoder’s Bi-Directional Communication characteristics when RailCom is enabled in [[{{NAMESPACE}}:CV_29|CV 29]].
+
This CV is used to configure decoder’s bi-directional communication characteristics when RailCom is enabled in [[{{NAMESPACE}}:CV_29|CV 29]].  
<br><br/>
+
 
*Note If the decoder does not support a feature contained in this table, it shall not allow the corresponding bit to be set improperly (i.e. the bit should always contain its default value).  
+
If the decoder does not support a feature contained in this table, it shall not allow the corresponding bit to be set improperly. E.G. if a decoder does not support RailCom, this CV will read 0 and will not accept any values to be programmed to it. Additionally, the decoder should not allow you to enable a feature within the table below which is not supported.
  
 
{| class="wikitable" style="text-align: center;"
 
{| class="wikitable" style="text-align: center;"
 
|-
 
|-
! scope="col"| Feature
+
!Bit
! scope="col"| Description
+
! scope="col" |Feature
! scope="col"| Default
+
! scope="col" |Description
! scope="col"| Value
+
! scope="col" |Default
 +
! scope="col" |Value
 +
!Supported by TCS
 +
|-
 +
|0
 +
! scope="row" |Channel 1
 +
|If enabled, Channel 1 will broadcast the address.
 +
|ON
 +
|1
 +
|YES
 +
|-
 +
|1
 +
! scope="row" |Channel 2
 +
|If enabled, Channel 2 will send and receive data and provide acknowledgements.
 +
|ON
 +
|2
 +
|YES
 +
|-
 +
|2
 +
!Auto Channel 1
 +
|Automatically Turn off Channel 1
 +
|ON
 +
|4
 +
|YES
 +
|-
 +
|3
 +
!(Reserved)
 +
|''Not Used''
 +
|N/A
 +
|8
 +
|
 +
|-
 
|-
 
|-
! scope="row"| Channel 1
+
|4
| If enabled, Channel 1 will broadcast the address.  
+
! scope="row" |Programming Address 3L
| ON
+
|If this setting is enabled, programming Long Address 3 will be allowed.
| 1
+
|OFF
 +
|16
 +
|
 
|-
 
|-
! scope="row"| Channel 2
+
|5
| If enabled, Channel 2 will send and receive data and provide acknowledgements.
+
!(Reserved)
| ON
+
|''Not Used''
| 2
+
|N/A
 +
|32
 +
|
 
|-
 
|-
 +
|6
 +
!Current Limit
 +
|If enabled, the higher current limit for RailCom will be enabled
 +
|OFF
 +
|64
 +
|
 
|-
 
|-
! scope="row"| Programming Address 253
+
|7
| Serves as a programming lock. If this setting is disabled, programming address 253 will be locked.
+
!Automatic Login
| ON
+
|If enabled, allows automatic login (RCN-218 or RailComPlus®)
| 16
+
|OFF
 +
|128
 +
|''(Under Devel.)''
 
|-
 
|-
  
 
|}
 
|}
<noinclude>
+
''Note: The table above is based upon the RailCom Specification RCN-217 and RCN-225 as of 01-16-2023 and as such is potentially subject to change. Additionally, the last column in this table "supported by TCS" is only true for current production decoders which support RailCom, and may be untrue for specific decoders and/or decoder versions ([[CV 7]], or [[Diesel Version 5:CV 110|CV 110]]/[[Diesel Version 5:CV 111|CV 111]]) designed using an older revision of RCN-217.''
 
[[Category:Standard CV]]
 
[[Category:Standard CV]]
</noinclude>
+
[[Category:Bitwise CV]]

Latest revision as of 01:56, 17 January 2023

CV 28
RailCom Configuration
Range of Values0-255
Accepted Values0-255
Default Value7 (Varies)

NMRA CV 28 - Bi-Directional Communication Configuration (RailCom®)

This CV is used to configure decoder’s bi-directional communication characteristics when RailCom is enabled in CV 29.

If the decoder does not support a feature contained in this table, it shall not allow the corresponding bit to be set improperly. E.G. if a decoder does not support RailCom, this CV will read 0 and will not accept any values to be programmed to it. Additionally, the decoder should not allow you to enable a feature within the table below which is not supported.

Bit Feature Description Default Value Supported by TCS
0 Channel 1 If enabled, Channel 1 will broadcast the address. ON 1 YES
1 Channel 2 If enabled, Channel 2 will send and receive data and provide acknowledgements. ON 2 YES
2 Auto Channel 1 Automatically Turn off Channel 1 ON 4 YES
3 (Reserved) Not Used N/A 8
4 Programming Address 3L If this setting is enabled, programming Long Address 3 will be allowed. OFF 16
5 (Reserved) Not Used N/A 32
6 Current Limit If enabled, the higher current limit for RailCom will be enabled OFF 64
7 Automatic Login If enabled, allows automatic login (RCN-218 or RailComPlus®) OFF 128 (Under Devel.)

Note: The table above is based upon the RailCom Specification RCN-217 and RCN-225 as of 01-16-2023 and as such is potentially subject to change. Additionally, the last column in this table "supported by TCS" is only true for current production decoders which support RailCom, and may be untrue for specific decoders and/or decoder versions (CV 7, or CV 110/CV 111) designed using an older revision of RCN-217.