Difference between revisions of "CV 22"

From Train Control Systems Documentation
Jump to navigation Jump to search
m
Line 1: Line 1:
 
{{Infobox CV
 
{{Infobox CV
|cv name= Consist Light Ctrl. (F0, F9-F12)
+
|cv name=Consist Light Ctrl. (F0, F9-F12)
|cv range=0-255
+
|cv range=0-63
|cv accepted=0-63
+
|cv accepted=0-255
|cv default=255
+
|cv default=59 (Varies for OEM)
 
}}
 
}}
  
 
==NMRA CV 22 - Consist Lighting Control for Function 0 and Function 9 through Function 12==
 
==NMRA CV 22 - Consist Lighting Control for Function 0 and Function 9 through Function 12==
This CV is used to configure what functions will respond to user input on the consist address. This particular CV affects F0 and F9-F12. For each Bit which is set, that function will respond to instructions addressed to the consist address. Each bit which is cleared indicates that the function will only respond to instructions addressed to the locomotive's base address. F0F is controlled by Bit 0, F0R by Bit 1, F9 by Bit 2, and F12 by Bit 5.  
+
This CV is used to configure what functions will respond to user input on the [[{{NAMESPACE}}:CV_19|Consist Address]]. This particular CV affects F0 and F9-F12. For each Bit which is set, that function will respond to instructions addressed to the consist address. Each bit which is cleared indicates that the function will only respond to instructions addressed to the locomotive's base address. F0F is controlled by Bit 0, F0R by Bit 1, F9 by Bit 2, and F12 by Bit 5.  
  
 
To determine which functions are active, use the table below and combine the values of the functions you would like to have active, and program the ''sum'' into CV21. By default, all functions are active on the consist address.  
 
To determine which functions are active, use the table below and combine the values of the functions you would like to have active, and program the ''sum'' into CV21. By default, all functions are active on the consist address.  
Line 62: Line 62:
 
*[[{{NAMESPACE}}:CV_24|Consist Deceleration Adjustment]]
 
*[[{{NAMESPACE}}:CV_24|Consist Deceleration Adjustment]]
  
[[Category:Standard CV]][[Category:Bitwise CV]]
+
[[Category:Standard CV]]
 +
[[Category:Bitwise CV]]

Revision as of 23:36, 24 August 2022

CV 22
Consist Light Ctrl. (F0, F9-F12)
Range of Values0-63
Accepted Values0-255
Default Value59 (Varies for OEM)

NMRA CV 22 - Consist Lighting Control for Function 0 and Function 9 through Function 12

This CV is used to configure what functions will respond to user input on the Consist Address. This particular CV affects F0 and F9-F12. For each Bit which is set, that function will respond to instructions addressed to the consist address. Each bit which is cleared indicates that the function will only respond to instructions addressed to the locomotive's base address. F0F is controlled by Bit 0, F0R by Bit 1, F9 by Bit 2, and F12 by Bit 5.

To determine which functions are active, use the table below and combine the values of the functions you would like to have active, and program the sum into CV21. By default, all functions are active on the consist address.

Bit Feature Value Default
0 Function 0 Forward 1 Control on Consist Addr
1 Function 0 Reverse 2 Control on Consist Addr
2 Function 9 4 Control on Consist Addr
3 Function 10 8 Control on Consist Addr
4 Function 11 16 Control on Consist Addr
5 Function 12 32 Control on Consist Addr

Related: