CV 10: Difference between revisions

From Train Control Systems Documentation
Jump to navigation Jump to search
m (1 revision imported)
No edit summary
 
Line 1: Line 1:
{{Infobox
{{Infobox CV
|title = NMRA CV 10
|cv name= BEMF Cutout
|header1 = BEMF Cutout
|cv range=0-126
|label2 = Range of Values
|cv accepted=1-126
|data2 = 0-255
|cv default=0
|label3 = Default Value
|data3 = 0
}}
}}


Line 11: Line 9:
Contains a value between 1 and 126 that indicates the speed step above which the back EMF motor control cuts off. When 14 or 28 speed steps are used the LSB's of the value are truncated appropriately. A value of 0 means BEMF is always active.
Contains a value between 1 and 126 that indicates the speed step above which the back EMF motor control cuts off. When 14 or 28 speed steps are used the LSB's of the value are truncated appropriately. A value of 0 means BEMF is always active.


[[Category:Standard CV]]
[[Category:Standard CV]][[Category:Motor]]

Latest revision as of 22:43, 16 July 2021

Lua error: Internal error: The interpreter exited with status 1.

NMRA CV 10 - BEMF Cutout

Contains a value between 1 and 126 that indicates the speed step above which the back EMF motor control cuts off. When 14 or 28 speed steps are used the LSB's of the value are truncated appropriately. A value of 0 means BEMF is always active.