CV 3

From Train Control Systems Documentation
Revision as of 21:47, 16 July 2021 by TCSDanM (talk | contribs) (1 revision imported)
Jump to navigation Jump to search
CV 3
Acceleration Rate
Range of Values0-255
Accepted Values0-255
Default Value20

NMRA CV 3 - Acceleration Rate

Determines the decoder's acceleration rate. The higher the value the longer it takes to accelerate.
This CV overwritten when the "Momentum Function" is pressed The formula for the acceleration rate shall be equal to (the contents of CV#3*.896)/(number of speed steps in use). For example, if the contents of CV#3 =2, then the acceleration is 0.064 sec/step for a decoder currently using 28 speed steps. If the content of this parameter equals "0" then there is no programmed momentum during acceleration.