CV 23

From Train Control Systems Documentation
Revision as of 21:12, 16 July 2021 by tcs>TCSDanM
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
NMRA CV 23
Consist Acceleration Adjustment
Range of Values0-255
Default Value0

NMRA CV 23 - Consist Acceleration Adjustment

This CV contains additional acceleration rate information that is to be added to or subtracted from the base value contained in Configuration Variable #3. This CV will only affect the momentum when CV19 is a non-0 value, meaning the decoder is configured for advanced consisting. The total momentum value can be calculated using the following formula:

([the contents of CV#23] multiplied by [0.896]) divided by (number of speed steps in use)

This is a 7 bit value (bits 0-6) with bit 7 being reserved for a sign bit (0-add, 1-subtract). The product of this formula is added to the value in CV 3. In case of overflow (CV23 + CV3 > 255), the maximum acceleration rate shall be used (255). In case of underflow (CV3 + (-)CV23 < 0) no acceleration shall be used (0). The expected use of this configuration is for changing momentum to simulate differing train lengths/loads. Consisted/MU's tend to pull/push more cars, and therefore can have simulated higher loads by using this configuration.

Related: